<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22211</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: X-axis stepper move timed out
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that the picker is not obstructed from moving across the table.
Resume, if that fails then remove media and select media removed, then
If problem persists, then power the machine off and on.
</text></DescriptionText>
</OperatorAction>
<Cause>
Failed to receive the 'picker x-axis movement complete' message
from GENINE 1 within the expected time.
</Cause>